1. Usage
AP029 thermal relay is used for overheat protection and controlling temperature for air-conditioner,freezer and other electric device which working in heavy humidity place.
2. Service Conditions
1. Relative humidity:100%
2. Atmospheric pressure:86-106KPA
3. Ambient temperature:-40-160℃
4. Working position:anywhere
3. Main Specifications:
1. Contractor formal :1D, 1H
2. Rated load:Resistance nature 220V 20A
3. Contact resisance:<=50M ohm
4. Insulation resistance : Normal temperature and humidity >=200M ohm
5. Dielectric withstand voltage:Normal 1800V AC
6. The error of the acting temperature:<=+-5℃
7. The error of resetting temperature:<=+-15℃
4. Overall and Assemble Dimensions