1. Usage
AP026 thermal relay used for overheat protection and controlling temperature in electric device. It turns on/off two phase same time.
2. Service Conditions
1. Relative humidity:<=95%
2. Atmospheric pressure:86-106KPA
3. Ambient temperature:0-200℃
4. Working position : anywhere
3. Main Specifications:
1. Contractor formal :2D,2H
2. Rated load : Resistance nature 220V 10A;220V 15A
3. Contact resisance:<=100M ohm
4. Insulation resistance :Normal temperature and humidity >=100M ohm
Heavy humidity>=2M ohm
5. Dielectric withstand voltage:Normal:1800VAC
4. Specification parameters:
The rang of the acting temperature | Error of acting temperature | The error of the resetting temperature (Lower more 10℃ than the acting temperature) | Testing way and the rate of rising temperature |
-20-220℃ | < 5℃ | 10-30℃ | Copper or testing 5-10℃/min |
5.Order Specification Notes:
AP026 | 2D | -100 |
Type | Contact formal | acting temperature |
6.Overall and Assemble Dimension