1. Usage
AP-036 thermal relay is the feeling temperature relay??which have small volume,super-thin,his thickness is 5mm,and which is mainly used for the overheat protection and controlling temperature in electric devices.
2. Service Conditions
1. Relative humidity:<=92%
2. Atmospheric pressure:86-106KPA
3. Ambiect temperature:0-120℃
4. Working position:anywhere
3. Main Specifications:
1. Contractor formal:1D,1H
2. Rated load :Resistance nature:220V 1A;220V 3A
3. Contact resisance:<=100M ohm
4. Insulation resistance :Normal temperature and humidity >=100M ohm
Heavy humidity>=2M ohm
5. Dielectric withstand voltage:Normal:1500V AC
6. Weight:5g
4. Specification parameters
The rang of the acting temperature | The error of the acting temp | The error of the resetting temp (Lower more 10℃ than the acting temp) | Testing way and the rate of rising temp |
-20~120℃ | ±5℃ | UP 10℃ | Tested by copper or dry box(1℃/2 min) |
5.Order Specification Notes:
AP-036 | 1D | -100 |
TYPE | Contact formal1 D-move(close)1 H-move(break) | the acting temperature |
6.Overall and Dimension