1. Usage
The time is mainly used for air conditioning, refrigeratory, drybox, household appliances. etc.
2. Service Conditions
1. Relative humidity:<=98%
2. Atmospheric pressure:86-106KPA
3. Ambiect temperature:0-55℃
4. Working position:anywhere
3. Main Specifications:
1. Rated voltage:220V 50HZ
2. Rated electricity:15A
3. Contact resisance:<=200M ohm
4. Insulation resistance :Normal temperature and humidity >=100M ohm
Heavy humidity>=2M ohm
5. Dielectric withstand voltage:Normal:1500V AC
6. Weight:100g
4. Time Range
Time range(h) | 1 | 2 | 3 | 4 | 6 | 8 | 10 | 12 | 24 | 48 |
Time precision(min) | 3 | 6 | 10 | 15 | 20 | 25 | 35 | 40 | 70 | 120 |
5. Overall and Assemble Dimension