Usage:
JUC-6F-D Compressor Overheat protector is mainly used for the overheat protection and temperature controlling in air-condition comressor of the automobile
Servic Conditions:
1 、Relative humidity:≤98%
2、Atmospheric pressure:86-106Kpa
3、Ambient temperature:-20-160℃
4、Working position:anywhere
Main Technical Specification:
1、Contact formal:1D 1H
2、Rated load:Resistance nature 220V 10A
3、Contact tesistance:≤50mΩ
4、Insulation resistance:Normal temperature and humidity ≥200MΩ
5、Dielectric withstand voltage:Normal 1000V/30S
Specification Parameters:
Acting temperature | Error of acting temperature | The rang of the resetting temperature | Testing way and the rate of temperature rising |
-20-160℃ | ±5℃ | Lower more10-20 ℃ than the acting temperature | Constant or oven testing(1℃/2min) |
Order Specification Notes:
JUC-6F-D | 1D | 130 |
Type | Contact formal | Acting temperature |
Overall and Assemble Dimension: